|
Question 1.
What two regulatory objectives are addressed by EmailXtender? (Choose two.)
A. retaining messages to generally accepted rules of evidence
B. blocking (quarantining) of email if it contains inappropriate content
C. ensuring privacy (encryption) of email as it moves across public infrastructure (Internet)
D. executing a discovery request against archived email records
Answer: A, D
Question 2.
Which of the following is stored within a volume?
A. Messages
B. Container Files
C. Indexes
D. Folders
Answer: A
Question 3.
You are an administrator for ITCertKeys.com. An archive task recently stopped running without completing and after re-running the task, it continues to stop without completing.
How do you determine why the task did not succeed?
A. run the task with Severe Errors Only selected in the Logging tab
B. run the task with Server Summary selected in the Logging tab
C. run the task again with Message Detail selected in the Logging tab
D. run the task with Mailbox Summary selected in the Logging tab
Answer: C
Question 4.
To recover the EmailXtender configuration, Which of the following is a resource that needs to be protected?
A. XML configuration files
B. Windows system registry
C. EmailXtender.ini file
D. SQL database
Answer: B
Question 5.
Which of the following results from the execution of chkidx -u
A. removes the monthly index for a particular month
B. repairs the indexes for the entire month
C. repairs only bad indexes within any given month
D. re-indexes every index
Answer: C
Question 6.
Which of the following allows you to delete all messages containing MP3 files from a mail server using EmailXtract?
A. Create a Deletion task, uncheck "verify archival before deletion," check "use all dates," and
enter *.mp3 in the attachment type.
B. Create a Deletion task, check the delete attachment type box, enter mp3 in the dialog box, and
make sure that "use all dates" is checked.
C. Create an Archival task, set the attachment type as *.mp3, and make sure that "use all dates"
is checked.
D. Create a Deletion task, check the box under the attachment types for MP3 files, and make
sure "use all dates" is checked.
Answer: A
Question 7.
You are an administrator for ITCertKeys.com. You use both the shortcut and delete tasks to implement EmailXtract.
What can be done to restore a deleted message?
A. The administrator can restore a message by running an EmailXtract Search task with the
"Restore Message" checkbox enabled.
B. The user can select the "Restore All" checkbox and then perform a search using the Search
Plug-In.
C. The user can restore a message from the Search Plug-In by using the "Copy Message to
Folder" function.
D. The administrator can perform an Archive Restore task from the EmailXtender Administrator.
Answer: C
Question 8.
Of the following, which product feature can be configured to carry out archival of historic email messages from restored back-up tapes in response to a legal discovery request?
A. EmailXaminer's message review function
B. EmailXtender's search client
C. EmailXtract's archive task
D. EmailXtract's analysis task
Answer: C
Question 9.
What occurs with the disposal of Monthly Data?
A. The index information is removed from the subdirectory of the EX install directory.
Associated SQL message data are not removed. Container files are removed from the storage
drive.
B. The index information is removed from the subdirectory of the EX storage directory.
Associated SQL message data are not removed. Container files are removed from the storage
drive.
C. The index information is removed from the subdirectory of the EX storage directory.
Associated SQL message data are also removed.
D. The index information is removed from the subdirectory of the EX install directory.
Associated SQL message data are also removed.
Answer: D
Question 10.
In EmailXtender, retention is set at which hierarchical level?
A. Cabinets
B. Monthly Data
C. Email Vault
D. Volumes
E. Folders
Answer: E
Question 11.
Which report provides details about sampling settings and Message Review Group Membership?
A. Group Membership report
B. Message Detail report
C. Configuration report
D. Group Activity report
Answer: C
Question 12.
Re-indexing the monthly data for a particular month is necessary due to the event log reporting that monthly index is corrupt. How would you achieve this using the EmailXtender Administrator?
A. in the monthly view, right click on the particular month, and select remove monthly index
B. in the volume view, right click and select dispose monthly data
C. in the volume view, right click and select re-index
D. in the monthly view, right click on the suspect month and select re-index
Answer: D
Question 13.
In a default configuration, what is recommended as the maximum number of users per EmailXtender server?
A. 15,000 users
B. 8,000 users
C. 5,000 users
D. 10,000 users
Answer: D
Question 14.
What are all the types of servers supported in EmailXtender's Domino Journaling?
A. Organizational, Site, Server, and Stand Alone Server
B. Site, Server, and Remote Server
C. Primary Partition Server, Remote Server, Secondary Partition Server, and Stand Alone Server
D. Primary Partition Server, Organizational, Site Server, and Stand Alone Server
Answer: C
Question 15.
What is the correct method of reprocessing messages that EmailXtender services was unable to process?
A. move messages from MsgCenter\Error to \MsgCenter\Collection\drop
B. move messages from MsgCenter\Lost and Found to \Inet\Pub\mailroot\drop
C. move messages from MsgCenter\Error to \MsgCenter\Collection
D. move messages from MsgCenter\BadDir to \InetPub\mailroot\drop
Answer: D
|
Question 1. From the EFI Boot Manager, how can you get information about the installed memory DIMMs? A. Go to the EFI Shell and enter: info mem B. It is not possible to get the information offline. C. The information displays automatically at the EFI Boot Manager menu. D. Go to the System Configuration menu and choose Memory Configuration. Answer: A Question 2. What does an amber blinking System LED on an Integrity rx2620 indicate? A. System is in error state B. Remote access is enabled C. A system warning D. Management Processor is powered off Answer: C Question 3. The rx3600 and rx6600 have LEDs which show the FRU Health status. How can you view the state of these LEDs remotely? A. From the MP main menu, select VFP B. From the MP main menu, select SL C. From the MP main menu, select CM, then LS D. From the MP main menu, select CM, then DF Answer: A Question 4. Where is the diagnostic panel on an Integrity rx4640 server located? A. top B. front C. back D. left side E. right side Answer: A Question 5. Where does HP OpenVMS store all error information? A. /var/adm/syslog/syslog.log B. SYS$ERRLOG:SYSTEM.LOG C. SYS$ERRORLOG:ERRLOG.SYS D. SYS$MANAGER:OPERATOR.LOG Answer: C Question 6. The diagnostic panel on an Integrity rx4640 shows a fan failure. What information on the Management Processor (MP) shows you when the fan failed? A. MP:CM> PS B. MP:CM> SS C. MP> SL --> L. Live Events D. MP> SL --> E. System Event Answer: D Question 7. You just installed an Integrity rx2620 server. How do you set the MP and system times? A. Use the MP date command to set time and date. B. The time will be set automatically during system boot. C. Use the EFI shell command time to set time and date of the MP. D. Use the MP date command to set the date, and use the MP time command to set the time. Answer: C Question 8. Which Offline Diagnostics Environment (ODE) utility should you use to test processors on an Integrity server? A. WDIAG B. IA64DIAG C. CPUDIAG D. PROCDIAG Answer: C Question 9. How can you determine the firmware version that is running on an HP Integrity system? (Select two.) A. At the EFI Boot Manager menu, open the EFI shell and enter info fw. B. At the MP main menu, open the Command Menu (cm) and enter firmware. C. At the EFI Boot Manager menu, go to the Firmware menu and select Version. D. At the EFI Boot Manager menu, go to the Firmware Configuration menu and select Version. E. If you access the EFI Boot Manager menu using iLO, the firmware versions display automatically. Answer: A, E Question 10. How can you access the UUID on an entry-level HP Integrity server? (Select two.) A. The UUID is written on the system information label of the server. B. At the EFI Boot Manager menu, access the EFI Shell; then enter info sys. C. At the Management Processor (MP) main menu, go to the Command Menu and enter id. D. At the EFI Boot Manager menu, access the System Configuration menu and select System UUID. E. If you access the EFI Boot Manager menu using integrated Lights-Out (iLO), the UUID displays automatically. Answer: A, B
Copyright © 2004 CertsBraindumps.com Inc. All rights reserved.