|
Question 1. Which 2 mirror devices are the boot disks for SPB on a CLARiiON CX600? A. 0_0_0 B. 0_0_1 C. 0_0_2 D. 0_0_3 Answer: B, D If it is SPA, then the answers are A&C, if it is SPB, then the answers are B&D. Question 2. Over what device is write I/O being transferred to the peer SP write cache on a FC4700? A. 12C bus B. CMI bus C. LCC card D. Internal serial port Answer: B Question 3. Exhibit: *** MISSING *** What is the function of the HA cache vault setting as shown in the image? A. Write cache is disabled if an SP fails. B. Write cache is not disabled if an SP fails. C. Write cache is disabled if single vault disk fails. D. Write cache is not disabled if single vault disk fails. Answer: D Question 4. Which CLI command is used to verify the installed software versions? A. navcli-h 192.168.1.1 ndu-list B. navcli-h 192.168.1.1 ndu-install C. navcli-h 192.168.1.1 ndu-check D. navcli-h 192.168.1.1 software-list Answer: A Question 5. What is a valid frontend SP ALPA address on CLARiiON FCC4700 series? A. 0 - 124 B. 0 - 128 C. 0 - 224 D. 0 - 255 Answer: A Explanation: ALPA = Arbitrated Loop Private Address. Some addresses are reserved for the backend connections, thus the full 0-128 are not available for the front end. Question 6. Which 2 mirror drives are the boot disks for SPB on a CLARiiON CX600? A. 0_0_0 B. 0_0_1 C. 0_0_2 D. 0_0_3 Answer: B, D Explanation: SP Boot Partitions - 2826.2 MB drives 0,1,2, & 3 - Each SP will have a mirrored SP boot partition. SPA will use drive 0 & 2 (0 is the primary with 2 as the mirror) and SPB will use drives 1 & 3 (1-primary, 3-mirror). Question 7. Which user account is needed to install drivers on UNIX servers? A. sys B. root C. oracle D. Administrator Answer: B Explanation: Oracle and Administrator are not default user accounts on UNIX. Root is the master, all-powerful account in UNIX. Question 8. Why is a snapview session lost an SP failure? A. The session was not persistent B. The host agent was not running C. The snapshot was not mounted D. The snapshot was not in a storage group Answer: A Explanation: Non-persistent sessions will not "trespass" over to the other SP. Options B, C, D have nothing to do with it. Question 9. Match the supported CLARiiON configurations. Choices may be used more than once. *** MISSING *** Answer: Pending, Send your comments or suggestions at feedback@itcertkeys.com Question 10. Which command allows for the extraction of all lines containing EMC case insensitive from the file test txt? A. vi test.txt B. ed test.txt -EMC C. grep EMC test.txt D. grep -I emc test.txt Answer: D Question 11. Exhibit: *** MISSING *** How is the metalun configured in the image? A. "Lun id" 65 and 75 are concatenated, Component 0 and 1 are striped B. "Lun id" 65 and 75 are striped, Component 0 and 1 are striped concatenated C. "Lun id" 2034 and 2035 are concatenated, Component 0 and 1 are striped D. "Lun id" 2034 and 2035 are striped, Component 0 and 1 are striped concatenated Answer: D Question 12. Which two [2] are valid methods of managing CLARiiON snapshots? A. navilcli B. admsnap C. admcilone D. admhosts E. java-jar navicli.jar Answer: A, B Question 13. How does the CLARiiON preserves data in write cache during a power failure of a CX600? A. The CX600 dumps the cache into the PSM B. The CX600 dumps the cache into the vault area C. The CX600 flushes the cache into the data disks D. The CX600 dumps the cache onto the reserved space Answer: B Question 14. What is the Power-on Sequence on the CLARiiON CX series? Steps, select from these Steps, place in order Answer: Steps, select from these Steps, place in order Question 15. What is the minimum amount of needs in a CLARiiON CX400 to have a host pare? A. 4 B. 5 C. 6 D. 15 Answer: C Question 16. Select three [3] items that are true about Snap View Clones. A. Uses CLI Provider NDU B. Can be mounted lat any time C. Uses COFW, Copy on First Write D. Must be exact same size of source LUNs E. Must use a minimum of one snap cache LUN F. Can only be created on an array with Access Longix Answer: A, D, F Explanation: A. Correct B. Wrong - Clones can not be mounted while synching (they must be fractured before they can be mounted) C. Wrong - Snaps use COFW D. Correct E. Wrong - snap cache LUNs are for SnapView Snaps, not clones F. Correct Question 17. What is the status of CX600 cache during the battery test in release 12? A. read cache gets disabled B. write cache gets disabled C. read and write cache are not disabled D. both read and write cache gets disabled Answer: D Explanation: During the SPS self-test (i.e. battery test), the SPS discharges and shows as Faulted in Navisphere. When an SPS faults, write cache at least is disabled. Question 18. Exhibit: *** MISSING *** What is the function of the "No install verify" select while binding a lun as shown in the image? A. It will not verify the alignment offset B. It will not verify contiguous free space C. It will not verify if the raidgroup was transitioning D. It will not do a background verify after the lun has been bound Answer: D Explanation: As soon as a LUN is bound on a CX-Series storage system running FLARE or Access Logix software version 02.05.x.xx.5.xxx or higher, a background verify runs automatically unless you disabled it with the –no initial verify switch. - or if you select "No install verify" in the GUI. Question 19. What is the ksh syntax to use vi commands for the shell history? A. set-o vi B. set-h vi C. set-hist vi D. export history=vi Answer: A Explanation: To enter the Korn shell and set up a working environment... ksh to start the Korn Shell set-o vito use vi to edit the command line set-o noclobber to prevent overwriting files with a > PS1='$PWD' to change prompt to current directory Question 20. Which CLI commands is used to verify the installed software versions? A. navcli-h 192.168.1.1 ndu-list B. navcli-h 192.168.1.1 ndu-installed C. navcli-h 192.168.1.1 ndu-check D. navcli-h 192.168.1.1 software-list Answer: A
|
Question 1. From the EFI Boot Manager, how can you get information about the installed memory DIMMs? A. Go to the EFI Shell and enter: info mem B. It is not possible to get the information offline. C. The information displays automatically at the EFI Boot Manager menu. D. Go to the System Configuration menu and choose Memory Configuration. Answer: A Question 2. What does an amber blinking System LED on an Integrity rx2620 indicate? A. System is in error state B. Remote access is enabled C. A system warning D. Management Processor is powered off Answer: C Question 3. The rx3600 and rx6600 have LEDs which show the FRU Health status. How can you view the state of these LEDs remotely? A. From the MP main menu, select VFP B. From the MP main menu, select SL C. From the MP main menu, select CM, then LS D. From the MP main menu, select CM, then DF Answer: A Question 4. Where is the diagnostic panel on an Integrity rx4640 server located? A. top B. front C. back D. left side E. right side Answer: A Question 5. Where does HP OpenVMS store all error information? A. /var/adm/syslog/syslog.log B. SYS$ERRLOG:SYSTEM.LOG C. SYS$ERRORLOG:ERRLOG.SYS D. SYS$MANAGER:OPERATOR.LOG Answer: C Question 6. The diagnostic panel on an Integrity rx4640 shows a fan failure. What information on the Management Processor (MP) shows you when the fan failed? A. MP:CM> PS B. MP:CM> SS C. MP> SL --> L. Live Events D. MP> SL --> E. System Event Answer: D Question 7. You just installed an Integrity rx2620 server. How do you set the MP and system times? A. Use the MP date command to set time and date. B. The time will be set automatically during system boot. C. Use the EFI shell command time to set time and date of the MP. D. Use the MP date command to set the date, and use the MP time command to set the time. Answer: C Question 8. Which Offline Diagnostics Environment (ODE) utility should you use to test processors on an Integrity server? A. WDIAG B. IA64DIAG C. CPUDIAG D. PROCDIAG Answer: C Question 9. How can you determine the firmware version that is running on an HP Integrity system? (Select two.) A. At the EFI Boot Manager menu, open the EFI shell and enter info fw. B. At the MP main menu, open the Command Menu (cm) and enter firmware. C. At the EFI Boot Manager menu, go to the Firmware menu and select Version. D. At the EFI Boot Manager menu, go to the Firmware Configuration menu and select Version. E. If you access the EFI Boot Manager menu using iLO, the firmware versions display automatically. Answer: A, E Question 10. How can you access the UUID on an entry-level HP Integrity server? (Select two.) A. The UUID is written on the system information label of the server. B. At the EFI Boot Manager menu, access the EFI Shell; then enter info sys. C. At the Management Processor (MP) main menu, go to the Command Menu and enter id. D. At the EFI Boot Manager menu, access the System Configuration menu and select System UUID. E. If you access the EFI Boot Manager menu using integrated Lights-Out (iLO), the UUID displays automatically. Answer: A, B
Copyright © 2004 CertsBraindumps.com Inc. All rights reserved.