Study Guides and Actual Real Exam Questions For Oracle OCP, MCSE, MCSA, CCNA, CompTIA


Advertise

Submit Braindumps

Forum

Tell A Friend

    Contact Us

 Home

 Search

Latest Brain Dumps

 BrainDump List

 Certifications Dumps

 Microsoft

 CompTIA

 Oracle

  Cisco
  CIW
  Novell
  Linux
  Sun
  Certs Notes
  How-Tos & Practices 
  Free Online Demos
  Free Online Quizzes
  Free Study Guides
  Free Online Sims
  Material Submission
  Test Vouchers
  Users Submissions
  Site Links
  Submit Site

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Online Training Demos and Learning Tutorials for Windows XP, 2000, 2003.

 

 

 

 





Braindumps for "PB0-200" Exam

Passed 960/1000 great success got from ITCertkeys

 Question 1.
Which two service advantages does a Symmetra UPS within Infrastruxure offer over traditional solutions?

A. Mean time repair is reduced
B. Built-in redundancy reduces component failures
C. The service bypass panel allows isolation of UPS
D. The required a Skill level for troubleshooting is reduced.

Answer: A, B

Question 2.
An enterprise data center manager is in charge of 47 production server several switches hubs routers and workstations.

The computer room is backed up by a symmetra PX 40KW with an external battery cabinet giving a runtime of about 22 minutes at full load. They do not have a generator. Forty-two of the 47 servers are critical and the manager wants to shut them down gracefully using his LAN, in order to not damage the operating systems.

Which application would you recommend?

A. Enterprise MANAGER
B. Power Chute Business Edition
C. Power Chute Network Shutdown
D. Power Chute Professional Edition

Answer: C

Question 3.
An office building has a chiller plant that supplies chilled water throughout the building for general cooling of the occupied spaces. The chilled water is not available outside regular business hours. A tenant is planning to occupy an office in the building,. The new tenant has a computer room for their IT support equipment that occupies 10 racks at an average of 2.7 KW per rack and runs 24 hours a day.

Which solution provides the greatest efficiency and reliability for the computer room?

A. roof-top unit
B. chilled-water unit
C. ceiling-mounted unit
D. glycol-cooled unit with economizer
E. refrigerant-based unit with secondary chilled-water cool

Answer: E

Question 4.
A site requires UPS power to feed a combination of desktop computer, existing rack mount server loads, and non-rack loads. Assume 35kw of combined load (20kw for servers and 15kw for PCs.) and a three -phase available source.

What is the highest available, easy-to=manage and easy-to-maintain solution?

A. all Smart-UPS and Back-UPS
B. one 40kw traditional UPS with one PDU for each load type
C. one 20kw three-phase single-module UPS system for each types of load
D. one 40kw N+1 Symmetra PX with overhead and under floor distribution

Answer: D

Question 5.
The basement air conditioning unit leaks water onto the data center floor. The facility manager wants to install a water sensor in the data center's basement and received e-mail notification through the company's LAN when there is water on the floor. The water sensor uses only normally open or normally closed contacts when water is detected.

What should the facility manager do?

A. connect a Network MANAGEMENT card for e-mail notification
B. install power net manager on an available computer for e-mail notification
C. connect a building management card to the water sensor for e-mail notification
D. connect an environmental monitoring unit to the water sensor for e-mail notification

Answer: D

Question 6.
ITCertKeys has a 15kw load requirement and wants a solution that will provide redundancy and room to expand.

Which solution provides enough capacity for a 15kw load and N+1 internal redundancy?

A. Symmetra PX with two power modules
B. Symmetra PX with three power modules
C. Symmetra Rack Mount with four power modules
D. Symmetra Rack Mount with three power modules

Answer: B

Question 7.
Exhibit:

 

Which diagram provides the best method of cooling the rack enclosures utilizing the Computer Room Air Conditioner (CRAC)?

A. I
B. II
C. III
D. IV

Answer: A

Question 8.
In an Infrastructure solution, what is the benefit of having two Main Intelligence Modules (MIMs)?

A. high available design
B. cleaner UPS output voltage
C. remote management of the UPS
D. integrated monitoring of distribution breakers

Answer: A

Question 9.
What is a 2N UPS system design?

A. a dual-input single module UPS
B. a parallel redundant UPS system consisting of two UPS modules
C. two independent UPS system feeding dual-corded power supplies
D. one single-module UPS feeding several dual-corded power supplies

Answer: C

Question 10. 
ITCertKeys has a 10-year-old computer room with a 30 cm raised-floor plenum.

They have just completed a change out of some IT equipment and also re-cabled much of the equipment with Cat5E and fiber. They are now having cooling problems in a few areas of the room.

What are two likely cause?

A. The new IT equipment draws air bottom to top, creating heat plumes around the racks
B. When the new cabling was added, the old cable was not pulled from the raised-floor plenum, 
     creating air dams.
C. Some of the new IT equipment is more dense and is generating more heat than the previous  
     equipment at that location.
D. The new fiber cable emits more heat than the previous copper network cabling, which causes  
     an increase in the temperature of the air leaving the perforated tiles.

Answer: B, C

Question 11.
Approximately how much cooling capacity does a 5-ton air conditioner have?

A. 12kw
B. 17kw
C. 20kw
D. 60kw

Answer: B

Question 12.
Exhibit:

 

What type of system is shown?

A. air cooled
B. water cooled
C. glycol cooled
D. remote condensing

Answer: A

Question 13.
Exhibit:

 

Which UPS topology is shown in the exhibit?

A. standby
B. line interactive
C. standby online hybrid
D. online double conversion

Answer: D

Question 14.
What is one advantage of using precision cooling rather than comfort cooling?

A. No humidity control is required
B. Reheat is available to increase humidity
C. Temperature control is within +/-0.5 degree Celsius (+/-1 degree Fahrenhit.)
D. Temperature control is within +/-0.3 degree Celsius (+/-5 degree Fahrenhit.)

Answer: C

Question 15.
What is the most common way rack-mounted IT equipment is cooled?

A. fans force air side to side
B. fans force air front to back
C. fans force air bottom to top
D. convection through its heat sinks front to back
E. convection through its heat sinks bottom to top

Answer: B

Question 16.
What is the correct formula to calculate Apparent Power (VA)?

A. Power (Apparent) = voltagexcurrent
B. Power (Apparent) =currentxResistance
C. Power (Apparent) =voltagexResistance
D. Power (Apparent) =currentxCapacitance

Answer: A


Google
 
Web www.certsbraindumps.com


Braindumps: Dumps for 2B0-019 Exam Brain Dump

Study Guides and Actual Real Exam Questions For Oracle OCP, MCSE, MCSA, CCNA, CompTIA


Advertise

Submit Braindumps

Forum

Tell A Friend

    Contact Us





Braindumps for "2B0-019" Exam

ES Policy Enabled Networking

 Question 1.
Authentication is used in Secure Application Provisioning to:

A. Quarantine malicious traffic
B. Persistently apply policy
C. Allow configuration of a switch's host data port
D. provide additional network access

Answer:  D

Question 2.
Saving a NetSight Atlas Policy Manager configuration to a .pmd file:

A. Writes the configuration to NVRAM on the switches
B. Allows for multiple configurations to be stored on the NMS
C. Notifies the RADIUS server that new policies have been created
D. Temporarily disables communication between all RADIUS clients until the save is complete

Answer:  B

Question 3.
Certificate services must be installed when using:

A. EAP-TLS
B. EAP-MD5
C. PWA
D. MAC authentication

Answer:  A

Question 4.
Persistent policy assignment:

A. Can be effective in an incremental deployment of acceptable use policy
B. Is dependent upon a RADIUS back-end configuration
C. Is deployed based on user authentication
D. Cannot be used on uplink ports

Answer:  A

Question 5.
A distinguishing characteristic of PEAP is:

A. It adds security by running over a VPN tunnel
B. It uses salt encryption
C. It requires that only the supplicant present a certificate
D. It creates keying material using the Pseudo-Random Function

Answer:  D

Question 6.
In the Enterasys policy-enabled network model, on-demand policy assignment:

A. Is the result of a manual configuration
B. Makes use of the Filter-ID parameter
C. Is overridden by a ports default role
D. Requires the use of 802.1X authentication mechanisms

Answer:  B

Question 7.
All of the following are services which make up the pre-configured Acceptable Use Policy service group EXCEPT:

A. Deny Spoofing
B. Permit Legacy Protocols
C. Limit Exposure to DoS attacks
D. Protocol Priority Access Control

Answer:  B

Question 8.
After configuration changes have been made in NetSight Atlas Policy Manager, what must be done before the changes take effect on the devices?

A. The NMS must be rebooted
B. The changes must be enforced
C. The changes must be verified
D. Nothing the changes take effect immediately

Answer:  B

Question 9.
In the three-level policy model, Enterasys maps:

A. The business/network level to classification rules
B. The service-provisioning level to roles
C. The device level to classification rules
D. All of the above

Answer:  C

Question 10.
The Active Edge consists of:

A. Policy-enabled switches
B. Core routers
C. SAP servers
D. User resources

Answer:  A


Google
 
Web www.certsbraindumps.com


Study Guides and Real Exam Questions For Oracle OCP, MCSE, MCSA, CCNA, CompTIA





              Privacy Policy                   Disclaimer                    Feedback                    Term & Conditions

www.helpline4IT.com

ITCertKeys.com

Copyright © 2004 CertsBraindumps.com Inc. All rights reserved.