Braindumps for "HP0-500" Exam

HP ProLiant Server Maintenance

 Question 1.
What is the likely cause of rack instability?

A. more than one component simultaneously extended
B. UPS installed at the bottom of the rack
C. side panels not installed
D. missing blanking panels

Answer: A

Question 2.
What are the best sources for the latest versions of Rompaqs and Softpaqs? Select two.

A. Compaq ResourcePaq
B. Smart Start
C. HP/Compaq website
D. QuickFind2000
E. OS ServicePaq

Answer: B, C

Question 3.
Which diagnostic mode tests individual components of a server?

A. Intermediate
B. Automatic
C. Quick Check
D. Prompted

Answer: D

Question 4.
Which utility is assists in planning and configuring Compaq racks?

A. Rack Manager
B. Rack Assistant
C. Rack Integrator
D. Rack Builder Pro

Answer: D

Question 5.
What enables remote server management and control regardless of the operating system or condition of the server?

A. CIM (Compaq Insight Manager)
B. SCU (System Configuration Utility)
C. Remote Utilities (from system Diagnostics menu)
D. RILOE (Remote Insight Light Out Edition option)

Answer: D

Question 6.
What can Compaq Diagnostics reliably test?

A. Compaq Insight Manager (CIM) agents
B. system ROM BIOS compatibility
C. DAT tape drive read/write function
D. non-Compaq SCSI controller

Answer: C

Question 7.
What capability do fans have in some hot-pluggable power supplies?

A. variable RPM, depending on thermal sensor readings
B. hot plug fan replacement
C. dual-power inputs for redundancy
D. redundant power supply fans

Answer: A

Question 8.
Which action is required to safely replace non hot-pluggable components in servers with redundant hot pluggable power supplies?

A. Depress server On/Off switch from front panel.
B. Ensure DC LED indicator on the hot-pluggable power supply is inactive.
C. Remove AC power cord from the primary hot-pluggable power supply.
D. Remove AC power cords from all hot-pluggable power supplies.

Answer: D

Question 9.
What do Compaq hot-pluggable power supplies have that traditional power supplies do not?

A. higher current
B. higher voltage
C. microcontroller Self-Test
D. power Monitor Port

Answer: C

Question 10.
Which network interface controller configuration can support redundant NICs?

A. one dual-port fast Ethernet network controller
B. one 16/4 token ring network controller connected to a managed hub
C. one fast Ethernet network controller connected to a second server
D. one fast Ethernet network controller connected to a router

Answer: A

Question 11.
What is the advantage of having an online spare as part of a SMART array configuration?

A. The drive can be used for temporary data storage until another drive fails.
B. The array will not lose its fault tolerance in case of a single drive failure.
C. You always have a spare drive available to physically put in place of a failed drive without having to order a
spare drive.
D. You can load balance across the array.

Answer: B

Question 12.
Which product reports prefailure on all Compaq SMART hard drives?

A. CIM
B. RBSU
C. ACU
D. SCU

Answer: A

Question 13.
After a field engineer adds a second array controller to the server, the operating system does not boot. 

What is the likely cause of the problem?

A. incorrect jumper settings
B. incorrect slot order
C. array controller boot order
D. interrupt conflicts

Answer: C

Question 14.
What is the available array space after grouping six 4GB hard drives using Advanced Data Guarding?

A. 12GB
B. 16GB
C. 20GB
D. 24GB

Answer: B

Question 15.
A hard drive fails on a system with an on-line spare. When is it recommended that the failed drive be replaced?

A. upon discovery of the failure
B. upon completion of rebuild of on-line spare
C. not needed, failed drive will perform self-repair
D. any time before rebuild of online spare is complete

Answer: B

Question 16.
Which resources could be used to help isolate correctable memory errors?

A. SSD and DAAD
B. ACU and SmartStart
C. Server Health Logs and Integrated Management Log
D. QRG (Quick Reference Guide) and Inspect

Answer: C

Question 17.
What problem is indicated if the server powers up with no video and an audible POST error?

A. memory module not seated
B. monitor signal cable not connected
C. intermittent memory parity errors
D. monitor in power saver mode

Answer: A

Question 18.
Which Compaq utility is used to configure Online Spare memory?

A. Rapid Raid Utility
B. Raid Builder for AMP
C. ROM-based Setup Utility
D. SmartStart

Answer: C

Question 19.
On a ProLiant 450 MHz processor server, Level 2 cache is logging errors. Which item should be replaced?

A. Cache Memory Stick
B. System I/O Board
C. CPU/Processor Module
D. Riser Card

Answer: C

Question 20.
While running Diagnostics on your ProLiant server, you receive an error code: 6092. What should you do?

A. Replace network card.
B. Replace disk controller.
C. Connect external loopback cable.
D. Place network card in a different slot.

Answer: C


Google
 
Web www.certsbraindumps.com


Braindumps: Dumps for 000-111 Exam Brain Dump

Study Guides and Actual Real Exam Questions For Oracle OCP, MCSE, MCSA, CCNA, CompTIA


Advertise

Submit Braindumps

Forum

Tell A Friend

    Contact Us





Braindumps for "000-111" Exam

IBM Systems Storage Distributed Systems v7

 Question 1.
What is the key advantage of implementing an IBM System Storage SAN Volume Controller rather than a DS4000 only storage configuration for a Business Continuity/Disaster Recovery solution?

A. 1024 LUN consistency group support for Metro Mirror
B. Dynamic RAID Migration
C. Space EfficientFlashCopy
D. Dynamic Volume Expansion

Answer: A

Question 2.
The client already has LTO2 and LTO3 tape drives and cartridges, but is concerned that LTO4 drives are too expensive. The client is currently favoring SDLT as a solution. 

What is the recommended response to this client?

A. Quantum manugactures LTO4 as well as SDLT
B. LTO4 can process the client's existing tape cartridge
C. IBM announced LTO4 in April 2007
D. SDLT is a single-hub cartridge technology

Answer: B

Question 3.
What is an advantage of IBM SAN Volume Controller (SVC) virtualization over an HP Enterprise Virtual Array virtualization?

A. SVC supports more RAID levels than HP EVA
B. SVC is a SAN virtualization at the network level
C. SVC is an IBMVirutalization solution for IBM Disks
D. SVC has a broader world-wide installation base than HP EVA

Answer: B

Question 4.
The client has installed an IBM System Storage SAN Volume Controller to virtualize DS400 disk systems attached to a Windows 2003 Server. 

Which method is recommended to confirm the appropriate multi-path driver is installed?

A. Issue the "datapath query adapter" command to confirm subsystem device driver (SDD) is 
    properly configured
B. Log in to the SAN Volume Controller master console
C. Issue the "powerpath" command to confirm both SVC and DS4000 are connected to each 
    other
D. Use DS4000 Storage Manager to verify that MPIO/DSM driver is running correctly

Answer: A

Question 5.
A client has reached maximum power capacity going into their data center which prevents further business growth. A new facility with greater power capacity will take 12 to 18 months to build. 

From an IT industry perspective, what is a description of short-term business objective that deals with this crisis?

A. Additional UPS units can be used to avoid power outage issues
B. Data can be archived to tape and stored outside the data center
C. A raised floor can use perforated tiles to increase air flow
D. Computer Room Air Conditioning (CRAC) units can be added to reduce temperature

Answer: B

Question 6.
Which resource provides information about the general availability date for a new IBM System Storage product?

A. Announcement Letter
B. Sales Manual
C. Competeline
D. Interoperability Matrix or Guide

Answer: A

Question 7.
A new client currently has a multi-tier storage environment consisting of EMC DMX subsystems. They are dissatisfied with the high costs of TimeFinder and additional disks in the DMX systems. 

Which solution would provide the lowest cost alternative for providing instant copies of the DMX LUNs for backups?

A. SVC withFlashCopy and a DS4700 with SATA drives
B. SVC withFlashCopy and a DS3400 with SATA drives
C. SVC withFlashCopy and a DS3400 and a DS3400 with Fibre Channel drives
D. N5600 Gateway withSnapShot feature with DS4800 Fibre Channel drives

Answer: B

Question 8.
A customer has a requirement for 8 TB if data to be stored on tape. The customer wants the most cost-effective automated LTO4 solution. 

Which solution meets the customer's requirements?

A. TS2340
B. TS3200
C. TS3310
D. TS3100

Answer: D

Question 9.
On the IBM System Storage Web Site, under which category would you find information about IBM System Storage SAN Volume Controller?

A. Network Attached Storage
B. Storage Area Network
C. Disk Systems
D. Software

Answer: D

Question 10.
An IBM System Storage DS4000 LUN connected to Linux server was dynamically expanded from 500 GB to 600 GB. 

Which Linux command confirms the change was performed correctly?

A. Route -n
B. Fdasd -p
C. Iostat
D. Df -h

Answer: D