Braindumps for "HP0-797" Exam

Enterprise Integration and Management of HP ProLiant Servers

 Question 1.
An enterprise class customer is setting up a new Fiber Channel SAN spanning multiple buildings that are 300m apart. 

Which Fibre cable type is the best choice based on functionality and cost?

A. multimode
B. single mode
C. GBIC
D. ultra-pure glass

Answer: A

Question 2.
Which feature of the HP ProLiant iLO Advanced Management pack will allow you to load new ProLiant Support packs from a Smart Start CD?

A. Virtual Machine Management
B. Virtual Media
C. Advanced patch management
D. Virtual Console
E. Directory Services integration

Answer: B

Question 3.
A Customer has two HP ProLiant DL580 G2's running as a Windows 2003 Cluster connected to a MSA1000. Each HP ProLiant DL580 G2 has two 36.4 GB hard drives on which the Windows 2003 operating system is installed. The cluster is currently offline. 

What could be the cause?

A. Both HP ProLiant DL580 G2 have failed over and failed back again more than 3 times in 5 
     minute.
B. The Inter mode communication paths (interconnects) is down
C. Both hard drives have failed in one of the HP ProLiant DL580 G2s
D. A host bus Adapter (HBA) has failed in one of he HP ProLiant DL580G2s

Answer: A
 
Question 4.
Which ProLiant Essentials tool should be considered during the last step of the HP troubleshooting methodology 6-step process?

A. performance Management pack
B. Vulnerability and patch Management pack
C. Insight Diagnostics
D. Virtual Machine manager
E. Rapid Deployment pack

Answer: B

Question 5.
When trying to install HP SIM on an HP ProLiant running Linux, an error message indicates that the installed version of Postgre SQL has the wrong version number. 

What is the appropriate step to correct this problem?

A. Remove the current version of Postgre SQL and restart the installation
B. Select the ignore option to continue with the installation
C. Select the replace option to continue with the installation
D. Add the latest version of Postgre SQL to the current version and restart the installation

Answer: A

Question 6.
In order for HP Systems Insight Manager to execute commands on managed systems by means of Distributes Task Facility (DTF), what must be configured on the managed system?

A. private SSH key
B. public SSH key
C. SNMP trap with READ capability
D. SNMP trap with WRITE capability

Answer: B

Question 7.
Which SAN solution service offerings does HP provide to enterprise customers?
Select THREE.

A. Heterogeneous SAN integration
B. Remote Repair
C. Integration of Applications
D. Automatic Disk Replacement
E. Remote Failover
F. Basic SAN deployment
G. Automatic SAN switch management

Answer: A, C, F

Question 8.
A customer is redeploying A ML370 G1 server and is trying to install Windows 2000. 

Which method should the customer use to get Windows 2000 installed with the latest HP supplied drives and tools?

A. Perform a Smart Start 5.5 assisted installation, then download and Install the latest ProLiant 
    Support pack (PSP)
B. Perform a Smart Start 7.1 assisted installation, then download and Install the latest ProLiant 
    Support pack (PSP)
C. Perform a Smart Start 6.2 assisted installation, then download and install the latest ProLiant 
    Support pack (PSP)
D. Use a Windows 2000 CD to perform the installation

Answer: A

Question 9.
The ProLiant Essentials Vulnerability and patch Management pack integrates with which HP product?

A. Rapid Deployment pack
B. Systems Insight Manager
C. Workload Management pack
D. Integrated Administrator

Answer: B

Question 10.
After replacing a 5302 array controller with a 6402 controller, you receive an error "Boot Controller.(Unknown Device)".

Which utility should you use to make sure the new array controller is set as the boot controller?

A. Array Configuration Utility
B. Array Diagnostic Utility (ADU)
C. ROM-Based Setup Utility (RBSU)
D. Smart Start

Answer: C

Question 11.
In Linux, which command will show the system IRQ assignments and the devices that are using those IRQs?

A. cat /proc/ioports
B. cat /proc/bus
C. cat /proc/devices
D. cat /proc/interrupts

Answer: D

Question 12.
ITCertKeys.com wants to upgrade five 18GB hard drives to 72GB hard drives without downtime on their SA5302.

What is the first step you should take when performing online Array Capacity Expansion?

A. Insert the 5 72GB drives and migrate the data in the Online Raid Configuration for Arrays 
     (ORCA)
B. Remove one 18GB hard drive at a time and replace with 72GB hard drive
C. Remove one 18GB hard drive and replace it with a 72GB drive
D. Backup all data to minimize the risk of losing data

Answer: D

Question 13.
Which MSA product supports SATA drives in a SAN environment?

A. MSA1000
B. MSA500
C. MSA30
D. MSA1500

Answer: D

Question 14.
On an MSA1000 configured with a single MSA Switch 2/8, how may servers can be connected to the MSA1000?

A. 2
B. 7
C. 4
D. 8

Answer: B

Question 15.
What is the airflow direction in the rack-mountable HP Proliant servers?

A. front to back
B. back to front
C. top to bottom
D. bottom to top

Answer: A

Question 16.
Which HP ProLiant Essentials tool detects and analyzes hardware bottlenecks on HP Proliant Servers?

A. Virtual Machine Management Pack
B. Performance management Pack
C. HP Systems Insight manager
D. Vulnerability and Patch Management Pack

Answer: B

Question 17.
Yon are consulting with ITCertKeys.com on the advantages of consolidating his aging datacenter servers into a HP Blade Systems solution.

What are the most important environment variables to consider? (Select two)

A. cooling
B. sound
C. power
D. installation and support options
E. serviceability

Answer: A, C

Question 18.
Which HP Proliant server family has been designed to run on 48V DC power?

A. BL family
B. DL family
C. ML family
D. CL family

Answer: A

Question 19.
You want to submit a Bill of Materials (BOM) with your proposal for implementing a p-Class HP Blade System.

Which utilities will help to build your solution and BOM? (Select two)

A. HP Consolidation tool
B. HP Enterprise Configurator
C. Rack/site installation preparation Utility
D. HP Custom Builder
E. HP Blade System sizing Utility

Answer: B, E

Question 20.
Which HP tool can help yon configure and size a ProLiant server to suit specific business needs?

A. ProLiant Essentials Foundation Pack
B. Enterprise Configurator
C. ProLiant Essentials Workload Management Pack
D. ProLiant Support Packs

Answer: B


Google
 
Web www.certsbraindumps.com


Braindumps: Dumps for 310-200 Exam Brain Dump

Study Guides and Actual Real Exam Questions For Oracle OCP, MCSE, MCSA, CCNA, CompTIA


Advertise

Submit Braindumps

Forum

Tell A Friend

    Contact Us





Braindumps for "310-200" Exam

Sun Certified System Administrator for the Solaris 10 OS, Part I

 Question 1.
You accidentally initiated an abort sequence. As a consequence, your SPARC-based SYSTEM WENT INTO THE prom MODE.

Which two actions disable the default keyboard abort sequence? (Choose two)

A. detach serial console device
B. run the kbd -a disable command
C. run the eeprom command to disable KEYBOARD_ABORT
D. in PROM mode, change the value of keyboard to disable
E. edit / etc/default/kbd to change the value of the variable KEYBOARD_ABORT to disable

Answer: B, E

Question 2.
Your x86-based system with Solaris 10 OS installed on it is not booting correctly. You think the problem might be that a BIOS setting is not correctly configured. 

What should you do to abort the boot process and reboot into the BIOS configuration menu?

A. While holding down the reset button, you power cycle the system.
B. You press the middle mouse button, When the screen times out, you enter the BIOS 
    configuration menu and examine the BIOS settings.
C. You press the stop-A keys then typ reset-all. You reboot directly into the BIOS configuration 
    menu and examine the BIOS settings.
D. You press the Ctrl-Alt-Del keys and reboot the system, or press the reset button. When the  
    screen tells indicates the key to enter the BIOS, you press it and examine your BIOS settings.

Answer: D

Question 3.
Given:
ap: : sysinit:/sbin/sutopush -f/etc/iu.ap
sp: : sysinit:/sbin/soconfig -f /etc/sock2path
smf: :sysinit:/lib/svc/bin/svc.startd >/dev/msglog 2<>/dev/msglog /dev/msglog 2<>/dev/msglog

Which two statements are true? (choose two)

A. This file must be read by the process inetd.
B. When booting this system, svc.startd will start.
C. This is a part of the content of the /etc/inittab file
D. This system starts/lib/svc/bin/svc.startd for run level 1.
E. When this system gets the powerfail signal, svc.startd will be respawned.

Answer: B, C 

Question 4.
There is a problem on a SPARC-based system that has several permanent, customized device aliases . The system's use of these aliases needs to be temporarily disabled, so that when the problem is cleared, they can be enabled without having to redefine them.

Which sequence of OBP commands temporarily disables the customized device aliases defined on the system?

A. use-nvramrc=false
    reset
B. use-nvramrc?=false
    reset
C. setenv use-nvramrc? false
    reset
D. setenv use-nvramrc? = false
    reset

Answer: C

Question 5.
An x86-based laptop has just had Solaris 10 OS installed. The graphics configuration has NOT been automatically detected and it is running without graphics.

Which program can you run to create an Xsun configuration file?

A. /user/X11/bin/Xserver
B. /user/dt/bin/xsession
C. /usr/x11/binxorgconfig
D. /usr/openwin/bin/kdmconfig
E. /usr/x11/bin/xorg -configure

Answer: D

Question 6.
The SPARC-based workstation system in your accounts department need their PROMs upgraded. Some of the systems fail to upgrade.

What is the cause?

A. The patch is corrupt.
B. The systems do not have enough memory
C. The write protect jumper has not been set correctly.
D. The system is running an earlier version of Solaris OS.

Answer: C

Question 7.
A SPARC-based system does not boot and displays the message:
"Timeout waiting for ARP/RARP packet"

Which three actions should you take to check the boot environment of the system? (Choose three)

A. check if the frame buffer is working properly
B. check if the NVRAM alias net is set properly
C. check if the NVRAM alias boot-file is set properly
D. check if the PROM variable boot-device is set properly
E. check if the PROM variable local-mac-address?

Answer: B, D, E

Question 8.
 

You receive a complaint from a user who is unable to use the SSH service to access the user's lab system. You use a serial line to get in and check the SSH service. The svcs output is shown in the exhibit.

What has caused the disruption of the SSH service?

A. The service is disabled.
B. The contract_id is missing
C. There is no "next state" defined
D. One of the dependencies has NOT been met.

Answer: D
As you can see /network/physical is disabled
One of dependencies has not been meet therefore ssh not running
So right answer is D

Question 9.
A SPARC-based system, but you are not sure of the physical path information;

Which OBP command shows you this information/

A. printenv
B. probe-all
C. show-devs
D. prtdiag -v
E. probe-scsi-all

Answer: C

Question 10.
As system administrator, you are asked to shut down the Apache HTTPD service that is running on a development server. You run the svcs grep apache command, and receive this output.
Legacy_run Feb_02 1RC:/ETC/RC3_D/S50APACHE

Based on this output, which two statements are tru?

A. This service is managed by LRC.
B. This service is NOT managed by SMF
C. Any legacy_run state can NOT be manually shut down.
D. In order to shut down this service, you need to execute the shutdown script in the /tc/init.d 
    directory
E. In order to shut down this service, you need to execute the following shutdown script svcadm –
    v disable /etc/init.d/s50apache

Answer: B, D